TS. Phase Adjacencies
Phase Adjacencies prevent underground mining and underground dumping. For example, you can mine Cutback1 and Cutback2 simultaneously, but Cutback2 cannot under-cut Cutback1. Similarly you can backfill a pit while it is being mined, but you can't dump underneath an unmined block.
Phase Adjacencies only set vertical dependencies between blocks. To finish an entire stage before another, see Custom Dependencies.Â
Example 1
Excavate Stage1 and Stage2 simultaneously, without undercutting Stage2 beneath Stage1:
Locate "Reserves/Mine1/Pit1/Stage2" in the Name column.
Select "Reserves/Mine1/Pit1/Stage1" in the Adjacent Stages dropdown list.
Example 2
Backfill Stage1 while it is being mined, with an offset of 50 metres between mining and dumping:
Locate "Dumps/Backfill1" in the Name column.
Select "Reserves/Mine1/Pit1/Stage1" in the Adjacent Stages dropdown list.
Set a standoff distance of 50 metres in the Dump→Pit Standoff column.
Â