APS Delays
Delays represent periods of time where equipment is not doing the primary function it was designed to do – i.e., drilling, loading, hauling.
Setup > Delays.
To add a Delay:
Press the blue plus icon.
Select the Name field and rename it – i.e. Crib Break.
Set delay configuration as per table definitions below.
Column | Description |
---|---|
Name | Name of the delay. |
Is Considered Available | Ticked - The delay duration will count towards Available Time. Unticked - The delay duration will count towards Down Time. |
Equipment Moved | Ticked - Equipment will disappear from the animation during the delay. Unticked - Equipment will appear grey in the animation throughout the delay. |
Power Type | On - Equipment is not powered off during the delay. Off - Equipment is powered off during the delay. |
Color | The color which will be used to represent the delay on the Gantt chart. |
The order of Delays in this list, impacts how overlapping delays are reported. Higher ranking delays will be reported before lower ones.